MODULE – Extension module of the REXYGEN system
Block SymbolLicensing group: STANDARD
Function Description
The REXYGEN system has an open architecture thus its functionality can be extended. Such
extension is provided by modules. Each module is identified by its name placed below the
block symbol. The individual modules are added to the project main file by connecting the
prev input with the Modules output of the EXEC block or with the next
output of a MODULE which is already included in the project. There can be only
one module connected to the next output of the MODULE block. The next output of
the last module in the project remains unconnected. This means that the modules
create a unidirectional chain which defines the order of initialization of individual
modules.
Input
prev | Input for connecting the module with the Modules output of the EXEC block or with the next output of the preceding module | Long (I32) |
Output
next | Output for connecting to the prev input of the succeeding module | Long (I32) |