MVD – Motorized valve drive

Block SymbolLicensing group: STANDARD
PIC

Function Description
The MVD block simulates a servo valve. The UP (DN) input is a binary command for opening (closing) the valve at a constant speed 1tv, where tv is a parameter of the block. The opening (closing) continues for UP=on (DN=on) until the full open y=hilim (full closed y=lolim) position is reached. The full open (full closed) position is signalized by the end switch HS (LS). The initial position at start-up is y=y0. If UP=DN=on or UP=DN=off, then the position of the valve remains unchanged (neither opening nor closing).

Inputs

UP

Open

Bool

DN

Close

Bool

Outputs

y

Valve position

Double (F64)

HS

Upper end switch

Bool

LS

Lower end switch

Bool

Parameters

y0

Initial valve position  0.0

Double (F64)

tv

Time required for transition between y=0 and y=1 [s]  10.0

Double (F64)

hilim

Upper limit position (open)  1.0

Double (F64)

lolim

Lower limit position (closed)  0.0

Double (F64)